Download Print this page

Effecta Komplett III 25kW Quick Start Manual page 18

Comissioning guide

Advertisement

Back end protection
Back end protection
If one or more heating circuits is connected to the
connections at the back of the boiler the back end
protection function must be enabled at all times.
NOTE: Warranty is void unless the back end protection
function is enabled.
Program setup - back end protection
Back end protection
Press anywhere on the controller and then open the HEA-
TING SYSTEM menu.
Depending on what sensors has been connected to the
boiler and what program options the system has been
set up with the HEATING SYSTEM menu will appear dif-
ferently. The one illustrated is displayed if one sensor G7
is attached and the programmer is set to a constant flow
temperature.
In the shunt control menu scroll down to BACKEND PROT
and press OK. In the BACKEND PROT menu make sure
that the function is set to YES.
Recommended settings:
Temp G1 min:
60°C
Max flow temp: 20°C
Description of function:
The first parameter (Temp G1 min) is the temperature
within the boiler where the Backend protection function
will be enabled. In the above example the function will be
activated when the temperature drops below
function will then restrict the flow temperature down to
the Max Flow temp which in the above example is set to
20°C. Since the draw of hot water is limited to a minimum
while the backen protection function is active the boiler
temperature (G1) will then rise and when the boiler tem-
peratures reaches 61°C the shunt motor will slowly start
to open again.
Boiler warranty is void if the backend protection function isn´t activated when heating
circuits are connected to the back connections of the boiler.
18
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
Shunt control 1
Program
Flow temp.
Radiator pump
Constant flow
Enegy saver
Backend prot.
Backend prot.
Backend prot.
Temp G1 min
Max flow temp.
60°C. The
Constant flow
22 (20)°C
On
60°C
>
Yes
Yes
60 °C
20 °C

Advertisement

loading

This manual is also suitable for:

Komplett iii 35kwKomplett iii 20kw