GE F60 Instruction Manual page 571

Ur series. feeder protection system
Hide thumbs Also See for F60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 25 of 70)
ADDR
REGISTER NAME
Data Logger (Read/Write Setting)
4181
Data Logger Channel Settings (16 items)
4191
Data Logger Mode
4192
Data Logger Trigger
4194
Data Logger Rate
Clock (Read/Write Setting)
419F
Synchronizing Source
Clock (Read/Write Command)
41A0
Real Time Clock Set Time
Clock (Read/Write Setting)
41A2
SR Date Format
41A4
SR Time Format
41A6
IRIG-B Signal Type
41A7
Clock Events Enable / Disable
41A8
Time Zone Offset from UTC
41A9
Daylight Savings Time (DST) Function
41AA
Daylight Savings Time (DST) Start Month
41AB
Daylight Savings Time (DST) Start Day
41AC
Daylight Savings Time (DST) Start Day Instance
41AD
Daylight Savings Time (DST) Start Hour
41AE
Daylight Savings Time (DST) Stop Month
41AF
Daylight Savings Time (DST) Stop Day
41B0
Daylight Savings Time (DST) Stop Day Instance
41B1
Daylight Savings Time (DST) Stop Hour
Fault Report Commands (Read/Write Command)
41B2
Fault Reports Clear Data Command
Oscillography (Read/Write Setting)
41C0
Oscillography Number of Records
41C1
Oscillography Trigger Mode
41C2
Oscillography Trigger Position
41C3
Oscillography Trigger Source
41C5
Oscillography AC Input Waveforms
41D0
Oscillography Analog Channel n (16 items)
4200
Oscillography Digital Channel n (63 items)
Trip and Alarm LEDs (Read/Write Setting)
42B0
Trip LED Input FlexLogic Operand
42B2
Alarm LED Input FlexLogic Operand
User Programmable LEDs (Read/Write Setting) (48 modules)
42C0
FlexLogic Operand to Activate LED
42C2
User LED type (latched or self-resetting)
42C3
...Repeated for User-Programmable LED 2
42C6
...Repeated for User-Programmable LED 3
42C9
...Repeated for User-Programmable LED 4
42CC
...Repeated for User-Programmable LED 5
42CF
...Repeated for User-Programmable LED 6
42D2
...Repeated for User-Programmable LED 7
42D5
...Repeated for User-Programmable LED 8
42D8
...Repeated for User-Programmable LED 9
42DB
...Repeated for User-Programmable LED 10
42DE
...Repeated for User-Programmable LED 11
42E1
...Repeated for User-Programmable LED 12
42E4
...Repeated for User-Programmable LED 13
42E7
...Repeated for User-Programmable LED 14
GE Multilin
RANGE
---
0 to 1
0 to 4294967295
15 to 3600000
0 to 3
0 to 235959
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
–24 to 24
0 to 1
0 to 11
0 to 6
0 to 4
0 to 23
0 to 11
0 to 6
0 to 4
0 to 23
0 to 1
3 to 64
0 to 1
0 to 100
0 to 4294967295
0 to 4
0 to 65535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
F60 Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
---
F600
---
1
F260
0 (Continuous)
---
1
F300
ms
1
F003
---
1
F623
---
1
F050
---
1
F051
---
1
F052
---
1
F114
---
1
F102
hours
0.5
F002
---
1
F102
---
1
F237
---
1
F238
---
1
F239
---
1
F001
---
1
F237
---
1
F238
---
1
F239
---
1
F001
---
1
F126
---
1
F001
---
1
F118
%
1
F001
---
1
F300
---
1
F183
2 (16 samples/
---
1
F600
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F127
1 (Self-Reset)
DEFAULT
0
0
60000
B
0 (None)
0
0
0
0 (None)
0 (Disabled)
0
0 (Disabled)
0 (January)
0 (Sunday)
0 (First)
2
0 (January)
0 (Sunday)
0 (First)
2
0 (No)
5
0 (Auto.
Overwrite)
50
0
cycle)
0
0
0
0
0
B-33