APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 13 of 70)
ADDR
REGISTER NAME
Remote Double-Point Status Inputs (Read/Write Setting Registers) (5 modules)
2540
Remote Double-point Status Input 1 Device
2541
Remote Double-point Status Input 1 Item
2542
Remote Double-point Status Input 1 Name
2548
Remote Double-point Status Input 1 Events
2549
... Repeated for Remote Double-point Status Input 2
2552
... Repeated for Remote Double-point Status Input 3
255B
... Repeated for Remote Double-point Status Input 4
2564
... Repeated for Remote Double-point Status Input 5
Phasor Measurement Unit Actual Values (Read Only)
256D
PMU 1 Phase A Voltage Magnitude
256F
PMU Unit 1 Phase A Voltage Angle
2570
PMU 1 Phase B Voltage Magnitude
2572
PMU 1 Phase B Voltage Angle
2573
PMU 1 Phase C Voltage Magnitude
2575
PMU 1 Phase C Voltage Angle
2576
PMU 1 Auxiliary Voltage Magnitude
2578
PMU 1 Auxiliary Voltage Angle
2579
PMU 1 Positive Sequence Voltage Magnitude
257B
PMU 1 Positive Sequence Voltage Angle
257C
PMU 1 Negative Sequence Voltage Magnitude
257E
PMU 1 Negative Sequence Voltage Angle
257F
PMU 1 Zero Sequence Voltage Magnitude
2581
PMU 1 Zero Sequence Voltage Angle
2582
PMU 1 Phase A Current Magnitude
2584
PMU 1 Phase A Current Angle
2585
PMU 1 Phase B Current Magnitude
2587
PMU 1 Phase B Current Angle
2588
PMU 1 Phase C Current Magnitude
258A
PMU 1 Phase C Current Angle
258B
PMU 1 Ground Current Magnitude
258D
PMU 1 Ground Current Angle
258E
PMU 1 Positive Sequence Current Magnitude
2590
PMU 1 Positive Sequence Current Angle
2591
PMU 1 Negative Sequence Current Magnitude
2593
PMU 1 Negative Sequence Current Angle
2594
PMU 1 Zero Sequence Current Magnitude
2596
PMU 1 Zero Sequence Current Angle
2597
PMU 1 Frequency
2599
PMU 1 df/dt
259A
PMU 1 Configuration Change Counter
259B
Reserved (4 items)
Phasor Measurement Unit Integer (Read Only)
2699
PMU 1 SOC Timestamp
269B
PMU 1 FRAMESEC Timestamp
269D
PMU 1 STAT Flags
Phasor Measurement Unit Aggregator Actual Values (Read Only)
26BD
PMU 1 Aggregator PDU Size
IEC 61850 GGIO5 Configuration (Read/Write Setting Registers) (16 modules)
26D0
IEC 61850 GGIO5 uinteger Input 1 Operand
26D1
IEC 61850 GGIO5 uinteger Input 2 Operand
26D2
IEC 61850 GGIO5 uinteger Input 3 Operand
26D3
IEC 61850 GGIO5 uinteger Input 4 Operand
26D4
IEC 61850 GGIO5 uinteger Input 5 Operand
GE Multilin
RANGE
1 to 32
0 to 64
1 to 64
0 to 1
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
2 to 90
-327.67 to 327.67
0 to 65535
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
---
---
---
---
---
F60 Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F001
---
1
F606
---
1
F205
---
1
F102
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
Hz
0.001
F003
Hz/s
0.01
F002
---
1
F001
---
1
F001
seconds
1
F003
seconds
1
F003
---
1
F003
---
---
F001
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
DEFAULT
1
0 (None)
"RemDPS Ip 1"
0 (Disabled)
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
B-21