APPENDIX A
Table A–1: FLEXANALOG DATA ITEMS (Sheet 11 of 22)
ADDRESS
FLEXANALOG NAME
8213
SRC 2 Vc Harm[25]
8672
Brk 1 Arc Amp A
8674
Brk 1 Arc Amp B
8676
Brk 1 Arc Amp C
8678
Brk 1 Op Time A
8679
Brk 1 Op Time B
8680
Brk 1 Op Time C
8681
Brk 1 Op Time
8682
Brk 2 Arc Amp A
8684
Brk 2 Arc Amp B
8686
Brk 2 Arc Amp C
8688
Brk 2 Op Time A
8689
Brk 2 Op Time B
8690
Brk 2 Op Time C
8691
Brk 2 Op Time
8784
HIZ Status
8785
HIZ Phase A Arc Conf
8786
HIZ Phase B Arc Conf
8787
HIZ Phase C Arc Conf
8788
HIZ Neutral Arc Conf
9024
Prefault Ia Mag [1]
9026
Prefault Ia Ang [1]
9027
Prefault Ib Mag [1]
9029
Prefault Ib Ang [1]
9030
Prefault Ic Mag [1]
9032
Prefault Ic Ang [1]
9033
Prefault Va Mag [1]
9035
Prefault Va Ang [1]
9036
Prefault Vb Mag [1]
9038
Prefault Vb Ang [1]
9039
Prefault Vc Mag [1]
9041
Prefault Vc Ang [1]
9042
Fault Ia Mag [1]
9044
Fault Ia Ang [1]
9045
Fault Ib Mag [1]
9047
Fault Ib Ang [1]
9048
Fault Ic Mag [1]
9050
Fault Ic Ang [1]
9051
Fault Va Mag [1]
9053
Fault Va Ang [1]
9054
Fault Vb Mag [1]
9056
Fault Vb Ang [1]
9057
Fault Vc Mag [1]
9059
Fault Vc Ang [1]
9060
Fault Type [1]
9061
Fault Location [1]
GE Multilin
UNITS
DESCRIPTION
%
Source 2 phase C voltage twenty-fifth harmonic
2
Breaker 1 arcing amp phase A
kA
-cyc
Breaker 1 arcing amp phase B
2
kA
-cyc
Breaker 1 arcing amp phase C
2
kA
-cyc
ms
Breaker 1 operating time phase A
ms
Breaker 1 operating time phase B
ms
Breaker 1 operating time phase C
ms
Breaker 1 operating time
2
Breaker 2 arcing amp phase A
kA
-cyc
Breaker 2 arcing amp phase B
2
kA
-cyc
2
Breaker 2 arcing amp phase C
kA
-cyc
ms
Breaker 2 operating time phase A
ms
Breaker 2 operating time phase B
ms
Breaker 2 operating time phase C
ms
Breaker 2 operating time
---
High impedance fault detection status
---
High impedance fault detection phase A arc confidence
---
High impedance fault detection phase B arc confidence
---
High impedance fault detection phase C arc confidence
---
High impedance fault detection neutral arc confidence
Amps
Fault 1 pre-fault phase A current magnitude
Degrees
Fault 1 pre-fault phase A current angle
Amps
Fault 1 pre-fault phase B current magnitude
Degrees
Fault 1 pre-fault phase B current angle
Amps
Fault 1 pre-fault phase C current magnitude
Degrees
Fault 1 pre-fault phase C current angle
Volts
Fault 1 pre-fault phase A voltage magnitude
Degrees
Fault 1 pre-fault phase A voltage angle
Volts
Fault 1 pre-fault phase B voltage magnitude
Degrees
Fault 1 pre-fault phase B voltage angle
Volts
Fault 1 pre-fault phase C voltage magnitude
Degrees
Fault 1 pre-fault phase C voltage angle
Amps
Fault 1 phase A current magnitude
Degrees
Fault 1 phase A current angle
Amps
Fault 1 phase B current magnitude
Degrees
Fault 1 phase B current angle
Amps
Fault 1 phase C current magnitude
Degrees
Fault 1 phase C current angle
Volts
Fault 1 phase A voltage magnitude
Degrees
Fault 1 phase A voltage angle
Volts
Fault 1 phase B voltage magnitude
Degrees
Fault 1 phase B voltage angle
Volts
Fault 1 phase C voltage magnitude
Degrees
Fault 1 phase C voltage angle
---
Fault 1 type
---
Fault 1 location
F60 Feeder Protection System
A.1 PARAMETER LISTS
A-11