Suction Head (View From Below); Electrode Overflow Protection; Suction Head, Filter Cover Opened - Kärcher NT 35/1 AP Te Service Manual

Hide thumbs Also See for NT 35/1 AP Te:
Table of Contents

Advertisement

5.3 Suction head (view from below)

1 Baffle plate
2 Flat fold filter
3 Container locking tab
4 Washer

5.3.1 Electrode overflow protection

Note
The appliance will switch off immediately if the con-
tainer is filled with enough fluid so that it touches both
electrodes. This is not the case, if non-conductive flu-
ids such as oils, greases and drilling emulsions are
vacuumed up.
The filling level must be continuously monitored and
the container must be emptied in time.
6
English 5.906-520.0 Rev. 00 (03/12)

5.4 Suction head, filter cover opened

1 Air outlet, working air
2 Flat fold filter
3 Rough dirt filter
4 AP filter cleaning system
5 Handle to open the filter cover
6 Hinge with stop bolt
7 Nameplate
8 Supply Cord
Note
For wet and dry vacuuming, the flat fold filter must al-
ways be installed.
Dry the flat fold filter after completion of the wet vac-
uuming.
To vacuum fine dust, you must use an additional pa-
per filter bag or a membrane filter (special accesso-
ry). These must always be removed prior to wet
vacuuming.