2-21. HIGH TEMPERATURE
LIMIT CONTROL
(Electric Units)
(Continued)
2-22. AUTOLIFT
ACTUATOR (MOTOR)
REPLACEMENT
(if applicable)
606
10. Uncoil capillary tube, starting at control, and insert through
pot fitting.
To avoid electrical shock or other injury, run the capillary
line under and away from all electrical power wires and
terminals. The tube must NEVER be in such a position
where it could accidentally touch the electrical power
terminals.
11. Carefully bend the capillary bulb and tube toward bulb holder
on heating elements.
12. Slip capillary bulb into bulb holder on heating elements.
Pull excess capillary line from pot and tighten nut into frypot
wall.
Be sure capillary bulb of high limit is located behind
capillary bulb of thermostat. Both capillary bulbs
and bulb holders should be positioned as not to interfere
with basket or when cleaning the frypot wall, or damage to
capillary tube could result.
13. With excess capillary line pulled out, tighten smaller nut hand
tight, then ¼ turn with wrench.
14. Replace front panel.
15. Refill with shortening.
1. Remove electrical power supplied to unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Drain shortening from frypot.
3. Remove baskets and using a large, flat-head screwdriver, push
the clevis pin through basket hanger. Using pliers,
pull pin from assembly.
Model OFE/OFG-321,322,323,324