2-5. POWER SWITCH
(Continued)
2-6. TEMPERATURE PROBE
REPLACEMENT
Electric
Gas
606
4. With control panel removed, and the wires off the switch, push
in on tabs on the switch to remove from panel.
5. Replace with new switch, and reconnect wires to switch.
6. Replace the control panel.
The temperature probe relays the actual shortening temperature to
the control board. If it becomes disabled, "E-6B" will show in the
display. Also, if the shortening temperature is out of calibration by
more than 10°F or C°, the temperature probe should be replaced.
An Ohm check can be performed also. See chart on page 2-7.
1. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Drain the shortening from the frypot.
3. Remove the control panel.
4. Using a 1/2" wrench, remove the nut on the compression
fitting.
5. Remove the temperature probe from the frypot.
6. Follow the appropriate instructions, on the following page,
depending upon the type of fryer, gas or electric.
Model OFE/OFG-321,322,323,324
2-5