1-3. TROUBLESHOOTING

PROBLEM
With the switch in
the POWER position,
fryer is completely
inoperative
Shortening will not
heat but lights are on
1-2
To isolate a malfunction, proceed as follows:
1. Clearly define the problem, or symptom and when it
occurs.
2. Locate the problem in the troubleshooting table.
3. Review all possible causes, then one at a time, work
through the list of corrections until the problem is solved.
If maintenance procedures are not followed correctly,
injuries and/or property damage could result.
CAUSE
 Open circuit
 Faulty contactor
(elec. model)
 Faulty gas control
valve (gas model)
 Faulty temperature
probe
 Faulty high limit
 Faulty drain switch
Model OFE/OFG-321,322,323,324
CORRECTION
 Check to see if unit is plugged in
 Check breaker or fuse at supply box
 Check POWER switch per Power Switch
Section; replace if defective
 Check voltage at wall receptacle
 Check cord and plug
 Check contactor per Heating Contactors
Section
 Check gas control valve per Gas Control
Valve Assembly Section
 Check temperature probe per Temperature
Probe Replacement Section; "E-6A or B"
 Check high limit per the appropriate High
Temperature Limit Control Section; "E-10"
 Check drain switch per Drain Microswitch
Section; "E-15"
203