2-18. HEATING ELEMENTS
(ELECTRIC ONLY)
(Continued)
203
3. Perform an ohm check on one element at a time, with wires
disconnected from element. If the resistance is not within
tolerance, replace the element.
Voltage
Wattage
208
4800
230
4800
Replacement:
Refer to figure 2-2.
1. Drain the shortening from the frypot.
2. Remove the high limit bulb holder from the heating element
inside the frypot.
3. Remove the heating element wires from the terminals by
removing the nuts and washers. Label each so it can be
replaced on the new element in the same position.
4. Remove the bolts from the five element spreaders. The
element spreaders will now pull off the elements.
5. Remove the brass nuts and washers which secure the ends of
the elements through the frypot wall.
6. Remove the heating elements from the frypot as a group by
lifting the far end and sliding them up and out toward the
rear of the frypot.
Always install new rubber O-rings when installing heater
elements.
7. Install new heating elements with the new O-rings, terminal
end first at approximately a 45 angle, slipping the terminals
through the front wall of the frypot.
8. Replace the brass nuts and washers on the element terminals.
Tighten the brass nuts to 30 foot lbs. of torque.
Model OFE/OFG-321,322,323,324
Resistance Ohms (cold)
9
11