Panasonic WV-V6430L Operating Instructions Manual page 71

Table of Contents

Advertisement

Refer to the following sheet for detailed information.
Parameter
Enable
Relay-in
Working period
Anti-dither
Sensor type
Record
Record Delay
Relay out
Alarm delay
Send Email
PTZ
Snapshot
Figure 7-53
After enabled, relay activation will work.
The default is Alarm 1.
This function becomes activated in the specified periods.
There are six periods in one day. Draw a circle to enable corresponding
period.
Select date. If you do not select, current setup applies to today only.
You can select all week column to apply to the whole week.
Note: User can set via dragging mouse while not releasing left mouse.
System only memorizes one event during the anti-dither period. The value
ranges from 0s to 100s.
There are two options: NO/NC. Switch from NO to NC means enabling
alarm; Switch from NC to NO means disabling alarm.
System auto activates motion detection channel to record once alarm
occurs (working with motion detection function).
System can delay the record for specified time after alarm ended. The value
ranges from 10s to 300s.
Enable alarm activation function. You need to select alarm output port so
that system can activate corresponding alarm device when alarm occurs.
System can delay the alarm output for specified time after alarm ended. The
value ranges from 10s to 300s.
After this function is enabled, system can send out email to alert you when
alarm occurs and ends.
Here you can set PTZ movement when alarm occurs. Such as go to preset x
when there is an alarm.
The event type includes: preset, tour and pattern.
After you enabled snapshot, the system will automatically snapshot if alarm
occurs.
Function