4.3.2

Tool Bar

Using the Tool Bar buttons is a more intuitive way to implement the
functions of ICOM Tools.
Port Select: Selects the port(s) you want to perform testing on
Port Setup: Sets up configuration of the port you have selected
Port Close: Closes the port you have selected
Port Run: Runs the port test on the port you have selected
Port Stop: Stops the port test on the port you have selected
All Ports Setup: Sets up the configuration of all ports not running test
All Ports Run: Runs test on all ports
All Ports Stop: Stops test on all ports
Clear Message: Clears messages on Message Logo area and the Rx length
information on the Performance Listing area
4.3.3

Com Port Tab

Each Com Port tab represents a specific port you have selected for test and configu-
ration. On the tab, you can see the Transfer Mode, Port Status, and Message Logo
area.
Transfer Modes
You can specify the transfer mode to be Normal, loopback (active) or loopback (pas-
sive).
Normal—allows data to be transmitted and received simultaneously. The data recep-
tion rate is helpful in identifying the performance of a communication card installed on
your system.
Loopback- In loopback mode a series of special data will be transmitted, which are
expected to appear on the receiving end. Using the loopback mode, you can check
the integrity of received data and find whether any error occurred on the transmission
line. The active loopback and passive loopback must work in pair to enable the loop-
back mode. When a port operates as active loopback mode, it will send data first and
31 PCI/ PCI Express-Communication User Manual