2
I
C - - W -
Bytes
16, 46
2
I
C - - W -
Bytes
17, 47
1 Bit
I
C - - W -
2
18, 48
I
C - - W -
Bytes
2
19, 49
O
C T R - -
Bytes
2
20, 50
O
C T R - -
Bytes
2
21, 51
O
C T R - -
Bytes
1 Bit
I
C - - W -
22, 52
C - - W -
1 Bit
I
23, 53
1 Bit
I
C - - W -
24, 54
1 Bit
O
C T R - -
C - - W -
25, 55
1 Bit
I
26, 56
1 Bit
O
C T R - -
27, 57
1 Byte
O
C T R - -
C T R - -
28, 58
1 Byte
O
1 Bit
O
C T R - -
29, 59
1 Bit
O
C T R - -
C T R - -
1 Bit
O
30, 60
1 Bit
O
C T R - -
31, 61
1 Bit
O
C T R - -
32, 62
1 Bit
O
C T R - -
33, 63
1 Bit
O
C T R - -
C T R - -
34, 64
1 Bit
O
2
65, 69, 73, 77
O
C T R - -
Bytes
66, 70, 74, 78 1 Bit
O
C T R - -
67, 71, 75, 79 1 Bit
O
C T R - -
68, 72, 76, 80 1 Bit
O
C T R - -
81
1 Byte
I
C - - W -
82
1 Byte
C T - - -
http://www.zennio.com
2=Standby
3=Economy
4=Protection
DPT_Value_Temp
-273.00 - 670760.00
DPT_Value_Temp
-273.00 - 670760.00
DPT_Step
0/1
DPT_Value_Tempd
-670760.00 - 670760.00
DPT_Value_Temp
-273.00 - 670760.00
DPT_Value_Temp
-273.00 - 670760.00
DPT_Value_Tempd
-670760.00 - 670760.00
DPT_Reset
0/1
DPT_Reset
0/1
DPT_Heat_Cool
0/1
DPT_Heat_Cool
0/1
DPT_Switch
0/1
DPT_Switch
0/1
DPT_Scaling
0% - 100%
DPT_Scaling
0% - 100%
DPT_Switch
0/1
DPT_Switch
0/1
DPT_Switch
0/1
DPT_Switch
0/1
DPT_Switch
0/1
DPT_Switch
0/1
DPT_Switch
0/1
DPT_Switch
0/1
DPT_Value_Temp
-273.00 - 670760.00
DPT_Alarm
0/1
DPT_Alarm
0/1
DPT_Alarm
0/1
DPT_SceneControl
0-63; 128-191
DPT_SceneControl
0-63; 128-191
[Tx] Setpoint
[Tx] Basic Setpoint
[Tx] Setpoint Step
[Tx] Setpoint Offset
[Tx] Setpoint Status
[Tx] Basic Setpoint Status
[Tx] Setpoint Offset Status
[Tx] Setpoint Reset
[Tx] Offset Reset
[Tx] Mode
[Tx] Mode Status
[Tx] On/Off
[Tx] On/Off Status
[Tx] Control Variable (Cool)
[Tx] Control Variable (Heat)
[Tx] Control Variable (Cool)
[Tx] Control Variable (Cool)
[Tx] Control Variable (Heat)
[Tx] Control Variable (Heat)
[Tx] Additional Cool
[Tx] Additional Heat
[Tx] PI State (Cool)
[Tx] PI State (Heat)
[Ix] Current Temperature
[Ix] Overcooling
[Ix] Overheating
[Ix] Probe Error
[Motion Detector] Scene Input
[Motion Detector] Scene Output
MAXinBOX FC 0-10V VALVE
Thermostat Setpoint Input
Reference Setpoint
0 = -0.5ºC; 1 = +0.5ºC
Float Offset Value
Current Setpoint
Current Basic Setpoint
Current Setpoint Offset
Reset Setpoint to Default
Reset offset
0 = Cool; 1 = Heat
0 = Cool; 1 = Heat
0 = Off; 1 = On
0 = Off; 1 = On
PI Control (Continuous)
PI Control (Continuous)
2-Point Control
PI Control (PWM)
2-Point Control
PI Control (PWM)
Temp >= (Setpoint+Band) => "1"
Temp <= (Setpoint-Band) => "1"
0 = PI signal 0%; 1 = PI signal greater than 0%
0 = PI signal 0%; 1 = PI signal greater than 0%
Temperature sensor value
0 = No Alarm;1 = Alarm
0 = No Alarm;1 = Alarm
0 = No Alarm;1 = Alarm
Scene Value
Scene Value