2.
Extend the end of the bracket beyond the end of the slide rail by 5/8 inch.
Repositioning allows the rack mount brackets to align with the rack posts.
FIGURE 21 Repositioning the L-brackets
1.
Three-hole slide mount L-bracket
2.
Locking hex nut, 8-32
Attaching the rail to round-hole rack posts
Perform the following steps to install the round-hole hardware.
1.
Position the outer slide rail inside the rack posts with the closed ends of the slide rail toward the non-port side of the rack, as
shown in the following figure.
2.
Loosen and adjust the position of the non-port side L-bracket as necessary.
NOTE
If side rack access is not available, measure the depth of the rack, loosen the L-bracket on the non-port side, and
adjust the bracket position until the total rail length matches the rack depth.
3.
Attach the L-brackets to the rack posts using five Phillips 10-32 x 1/2 in. screws and two of the three-hole rack nut bars.
NOTE
Leave the middle hole empty on the port side for securing the rack mount bracket later (refer to
the rack
4.
Tighten the screws to 15 in-lbs (17 cm-kgs).
Brocade 300 Hardware Installation Guide
53-1000862-12
on page 42).
Slide Rack Mount Kit (XBR-R000070)
3.
Outer slide rail
4.
5/8-inch reposition
Inserting the device in
37