Air Filter Maintenace- Basic Model; Separator Element Replacement; Drive Coupling Installation - Sullair ES-8-15L Operator's Manual And Spare Parts List

Es-8 series. rotary screw air compressor. standard and basic models 15, 20, 25 and 30 hp 11, 15, 18.5 and 22kw
Table of Contents

Advertisement

Figure 8-4 Air Filter- Basic Model (02250069-934)
*Replacement Element P/N 02250094-135
sure by closing recommended discharge shut-off
valve and releasing all internal pressure from
compressor.
ELEMENT INSPECTION- STANDARD MODEL
1. Place a bright light inside the element to inspect
for damage or leak holes. Concentrated light will
shine through the element and locate any holes.
2. Inspect all gaskets and gasket contact surfaces
of the housing. Should faulty gaskets be evident,
correct the condition immediately.
3. If the clean element is to be stored for later use, it
must be stored in a clean container.
4. After the element has been installed, inspect and
tighten (if necessary) all air inlet connections
prior to resuming operation.
AIR FILTER ELEMENT REMOVAL- STANDARD
MODEL
1. Clean the exterior of the air filter housing.
2. Remove the dust cap by loosening the securing
wingnut.
3. Pull element from body.
4. Clean the interior of the body by using a damp
cloth. DO NOT use compressed air to remove
the dirt.
5. Inspect the element; replace with new element if
necessary.
6. Re-position element into the body.
7. Replace dust cap.
8. Replace wingnut.
9. Clean inside of dust cap.
AIR FILTER MAINTENANCE- BASIC MODEL
Refer to Figure 8-4. Air filter (P/N 02250069-934)
maintenance should be performed every 6 months
or more frequent if conditions so require.
ELEMENT INSPECTION- BASIC MODEL
1. Place a bright light inside the element to inspect
for damage or leak holes. Concentrated light will
shine through the element and locate any holes.
MAINTENANCE
2. If the clean element is to be stored for later use, it
must be stored in a clean container.
AIR FILTER ELEMENT REMOVAL- BASIC MOD-
EL
1. Clean the exterior of the filter base and cover.
2. Loosen/remove the wingnut, washer and cover.
3. Remove element shield and element.
4. Clean filter base with a damp cloth. DO NOT use
compressed air to remove the dirt.
4. Inspect the element; replace with new element if
necessary.
5. Position element and pre-filter element in place.
6. Position cover over pre-filter element.
7. Reinstate washer and wingnut; tighten to secure.

SEPARATOR ELEMENT REPLACEMENT

Refer to Figure
8-5.
The separator should be
changed once a year. Follow the procedure ex-
plained below for element replacement.
!
WARNING
Before doing compressor maintenance, discon-
nect compressor from power source and lock out
power source. Isolate compressor from line pres-
sure by closing recommended discharge shut-off
valve and releasing all internal pressure from
compressor.
1. Insert a 100mm maximum length, 6mm diameter
pin into the radially drilled hole in the separator
cap. Loosen, unscrew counterclockwise and re-
move the cap.
2. Pull out the old element by gripping the end of the
element with channel lock pliers or a similar tool.
3. Install new o-rings on separator cap and separa-
tor element filter and oil lightly to make installa-
tion easier.
4. Insert and push the new element in place.
5. Reinstall the cap. Hand tighten using a 100mm
maximum length, 6mm diameter pin in the radial-
ly drilled hole.

DRIVE COUPLING INSTALLATION

Refer to Figure 8-6. For coupling installation the
tools required will be one set of metric Allen
Figure 8-5 Separator Element
*Repair Kit P/N 02250106-791
Section 8
29

Hide quick links: