6.1 INTRODUCTION

While Sullair has built into this compressor a com-
prehensive array of controls and indicators to as-
sure you that it is operating properly, you will want to
recognize and interpret the reading which will call for
service or indicate the beginning of a malfunction.
Before starting your Sullair compressor, read this
section thoroughly and familiarize yourself with the
controls and indicators - their purpose, location and
use.
6.2 STANDARD PARAMETER SETUP
Pressing the program key enters parameter display
and edit mode. To move to the next parameter press
the program key. To increment a parameter press
the up arrow key or logo key. The logo key will incre-
ment by 10. To decrement the value press the down
arrow key.
The parameters are displayed in the following order:
S Unload pressure - The pressure where
the machine is unloaded. For example if
this parameter is set to 110 psi the machine
will unload when the line pressure is above
110 psi.
UNLOAD
100 PSI
S Load differential - The pressure differen-
tial below the unload pressure where the
machine is loaded. For example, if the un-
load pressure is set to 110 and the load dif-
ferential is set to 10, the machine will load
when the line pressure goes below 100 psi.
LOAD
10 PSI
S P1 Max - Maximum sump pressure. An
alarm and shut down will occur when the
sump pressure rises above this pressure.
P1 MAX
135 PSI
S Wye to delta transition timer - For full
voltage starters this parameter is set to 0.
WYE DELT
10 SEC
S Restart time - Time to wait after power up
before starting machine. This parameter is
used to keep several machines from start-
ing at the same time after power up, or to
delay start until other equipment is started.
If disabled the machine will not automatical-
COMPRESSOR OPERATION-
ly start after power up.
RST TIME
10 SEC
S Unload Stop Timer - If the machine is run-
ning in AUTO mode, this parameter speci-
fies the amount of time that the machine will
run unloaded before shutting off. If the time
is set less than 15 minutes (for example five
minutes), there may be times when the ma-
chine will run unloaded for more than five
minutes. This is because there is another
timer that keeps the machine from being
started more than four times an hour.
UNLD TIM
15 MIN
S Language select - English, German,
Spanish, Italian and French may be se-
lected for display language.
LANGUAGE
ENGLISH
S Units - English or metric units may be se-
lected.
UNITS
ENGLISH
S Communications ID # - This is the net-
work address of a machine. If there is more
than one machine connected to the net-
work, each machine must have a unique
number.
COM ID #
S Communications baud rate - This should
always be selected to 9600 baud for all se-
quencing modes. It may be lower for slave
or monitoring modes.
BAUDRATE
6.3 SEQUENCING PARAMETERS SETUP
The following parameters are only available on de-
luxe model Supervisor II.
S Sequence method - This parameter sets
the method used for sequencing. The
choices
are
SLAVE, HOURS, COM ID#. See the Se-
quencing & Protocol Manual (See Recom-
Section 6
SUPERVISOR II
1
9600
DISABLED,
REMOTE,
21