Introduction; Troubleshooting - Sullair ES-8-15L Operator's Manual And Spare Parts List

Es-8 series. rotary screw air compressor. standard and basic models 15, 20, 25 and 30 hp 11, 15, 18.5 and 22kw
Table of Contents

Advertisement

9.1 INTRODUCTION

The information contained in the Troubleshooting
chart is based upon both the actual applied situa-
tions and extensive testing at the factory. It contains
symptoms and usual causes for the described prob-
lems. However DO NOT assume that these are the
only problems that may occur. All available data
concerning the trouble should be systematically
analyzed before undertaking any repair or compo-
nent replacement procedures.
A detailed visual inspection is worth performing for

9.2 TROUBLESHOOTING

SYMPTOM
T1 HI Message
P1 HI Message
SEP MNTN Message
P1, P2, P3 FAIL
almost any problems which may prevent unneces-
sary damage to the compressor. Always remember
to:
a.Check for loose wiring.
b.Check for damaged piping.
c.Check for parts damaged by heat or an electrical
Should your problem persist after making the rec-
ommended check, consult your nearest Sullair rep-
resentative or the Sullair Corporation factory.
PROBABLE CAUSE
Discharge Temperature Exceeded
225°F (107°C) for Pre-Alarm
Discharge Temperature Exceeded
235°F (113°C) for Shutdown
Ambient temperature exceeded
105°F (41°C)
Fluid Level in Sump is Too Low
Thermal Valve Malfunctioned
Cooler Fins are Dirty
Water Flow is Low (water-cooled
packages only)
Water Temperature is High (water-
cooled packages only)
Cooler is Plugged (water-cooled
packages only)
Temperature RTD Malfunction
Discharge Pressure Exceeded
Shutdown Level Because:
P1 MAX-3psi (0.2 Bar) Exceeded
for Pre-Alarm
P1 MAX Exceeded for Shutdown
Unloading Device (i.e., Blowdown
Valve, Sullicon Actuator, Optional
Spiral Valve) Failed to Operate
Pressure Regulator Maladjusted
Solenoid Valve Failed
to Operate
Control Air Signal Leaks
Control Air Signal Filter Clogged
Plugged Separator
dP1 > 10 psi
Pressure Transducer Malfunction
TROUBLESHOOTING
hort circuit, usually apparent by discoloration or a
burnt odor.
REMEDY
Improve local ventilation (i.e.,
remote intake of process and/or
cooling air.
Check/correct fluid level.
Check/replace thermal valve.
Clean cooler fins.
Check cooling water supply (i.e.,
closed valves).
Increase water flow, lower water
temperature.
Clean tubes and/or shell - if tube
plugging persists, provide cleaner
water.
Check connections from RTD.
If adequate, replace RTD.
Check operation of unloading device.
Check operation of pressure regulator.
Check operation of solenoid valve.
Check tubework feeding control
signal for leaks.
Service filter assembly.
Replace separator elements.
Check P1 & P2 pressure transducers.
Check connections from transducer.
If connections are good, replace transducer.