TECHNICAL SERVICE MANUAL FOR MASTERTIG ACDC
TROUBLESHOOTING CHART
PROBLEM
Remote control unit is not operating
properly.
Machine is overheating. Signal lamp
for thermal protection is on even if
the duty-cycle time has not been
exceeded.
There are occasional disturbances
during welding, set value is not
stable or arc is intermittent.
Arc is stopping intermittently.
Welding quality is bad in all methods:
arc is not stable
bad arc start
not enough arc voltage
lack of power
CAUSE
Defective remote control unit, faulty
control cable or faulty control card
A003 in Mastertig ACDC.
Faulty function panel.
Selection for remote unit type is not
correct.
Fuse F001, 0.8A, blown.
Faulty cooling fan(s) or PCB A002.
Loose connector.
Remote control unit is faulty
Faulty start switch in
torch.
TIG
Broken/faulty
torch, loose start
TIG
wire(s) in
torch.
TIG
Faulty Reed relay, K001.
One mains phase is missing or
mains cable is cut or loose.
Faulty main switch, S001, or primary
rectifier, VG101/G001.
Faulty capacitor C003.
Blown diode(s) in the secondary
rectifier G002, G003 or G004.
Gas is missing or gas leakage in the
TIG torch.
Broken/untightened earth cable or
earth clamp.
REMEDY
Check and repair the remote control
unit and cable according to TABLE
3.
Change PCB A003 in Mastertig
ACDC.
Check the function panel, see
TABLE 1, that the switching for
selection for local/remote is working.
Change the panel membrane if
needed.
See the paragraph SELECTION OF
REMOTE CONTROL UNIT.
Check and change the fuse if
necessary.
Check the 24 VDC voltage from fan
connectors: X9 between pins 3 and
4, another between 6 and 7, if it is
all right change the fan(s), if it is
not change the PCB.
Check/repair the control cable and
remote control unit according to
TABLE 3.
Check and change the start switch if
needed. See also TABLE 2.
Check and tighten the start wire(s)
inside the
torch.
TIG
Check it by opening the connector
X009, change reed relay if needed.
Check all mains phases from
terminal block X001. Change mains
fuse if needed, tighten mains cables.
Check using multimeter that S001 is
all right, check also that all diodes in
primary rectifier are functional.
Check/change capacitor C003.
Check and change diode blocks
according to APPENDIX 1.
Check gas flow and solenoid valve
as described earlier. Repair/change
TIG torch if needed.
Check and change the earth clamp
and the cable if necessary.