Table 2-1: Mediant 2000 Front View Component Descriptions
Item #
Label
1
FAULT
2
--
3
--
4
--
5
--
6
T1/E1 STATUS
7
ETH
--
8
--
9
--
10
--
11
2.1.1
Mediant 2000 Chassis
The Mediant 2000 chassis is an industrial platform that is 19" wide, 1U high and 12" deep.
The chassis houses the TP-1610 blade in its front cage in slot #1 (the lower slot), and the
TP-1610 RTM in its rear cage in slot #1 (the lower slot).
The Mediant 2000 chassis' Slot # 2 in the front and rear cages can optionally be used by
customers for a CPU blade.
The table below describes the chassis' LED indicators.
Location
Right side of front panel
Right side of front panel
Left side of front panel
2.1.2
Power Supply
The Mediant 2000 power supply is available in three configuration options:
Single universal 100-240 VAC, 1 A max, 50-60 Hz
Dual-redundant 100-240 VAC, 1.5 A max, 50-60 Hz
-48 VDC power supply suitable for field wiring applications
SIP User's Manual
Dual AC Power LED
cPCI blade locking screws
cPCI latches
TP-1610 cPCI blade, 16-trunk configuration
Status LED Indicators
E1/T1 Trunk Status LED Indicators
Ethernet LED Indicators
Reset button
cPCI LED Indicators
Power and Fan LEDs
An available cPCI slot for an optional third-party CPU blade
Table 2-2: Chassis LEDs Description
Color
Color
On
The power is on.
Green
At least one of the internal fans has significantly
On
Red
reduced its speed or has stopped (i.e., fan failure).
One of the two AC redundant power supplies is
faulty or disconnected from the AC/mains outlet
On
Red
(i.e., power supply failure). This LED is only
relevant for the dual AC power supply.
20
Mediant 2000 & TP-1610 & TP-260/UNI
Component Description
Description
Document #: LTRT-68806