Initialize The Storwize V7000; Initialize The File Modules; Enclosure; Modules - IBM Storwize V7000 Quick Installation Manual

Table of Contents

Advertisement

Initialize the Storwize V7000

Initialize the file modules

|
|
|
|
|
|
|
50
Storwize V7000 Unified: Quick Installation Guide
Table 10. Create two files and enter one line each, adjusted to the values fitting to your
environment.
Filename
Content
satask.txt
satask mknascluster -clusterip 9.111.160.10 -mask 255.255.248.0 -gw
9.111.167.254 -consoleip 9.111.160.50
Where:
v clusterip = Storwize V7000 IP address
v mask = Storwize V7000 subnet mask
v gw = Storwize V7000 gateway address
v consoleip = File module management IP address
cfgtask.txt
cfginit --ip=9.111.160.50 --netmask=255.255.248.0 --gateway=9.111.167.254 --
serviceip1=9.111.160.51 --serviceip2=9.111.160.52 --internalips=10.254.0.1 --
storwizeip=9.111.160.10
Where:
v ip = File module management IP address
v netmask = Storwize V7000 subnet mask
v gateway = Storwize V7000 gateway address
v serviceip1 = File module 1 IP address
v serviceip2 = File module 2 IP address
v internalips = Internal IP address range
v storwizeip = Storwize V7000 IP address
This document guides you through initializing the enclosures.
After the Storwize V7000 control enclosure has completed booting. You can verify
this by checking that the power LED is solid green and the status LED is blinking
green on each of the node canisters. Insert the USB key into either USB connector
(located at the back of the Storwize V7000 control enclosure) on the upper canister
(node 1). While the clustered system is being created, the red/amber fault LED, on
the node canister flashes (the middle light, at the rear of the unit designated by the
!). When the red/amber fault LED stops flashing, proceed to "Initialize the file

modules."

To initialize the file modules follow these procedures.
1. Verify that the blue LEDs at the front of the file modules are flashing. If both
are flashing, go to step 2 now. Do not insert the USB key unless both file
modules blue LEDs are flashing. If both LEDs are not flashing, allow at least 30
minutes for a full boot cycle. If both LEDs are still not flashing, reboot the file
module that is not flashing and allow 30 minutes for a boot cycle. Continue
with step 2 once both LEDs are flashing. If the problem persists, call support.
2. Insert the USB key that was used to configure the Storwize V7000 control
enclosure into file module 1 (the lower of the two file modules). Use any of the
file module's USB ports.
3. The following sequence should occur: