Section 2 - Familiarization
Base Control Console
Test Off/Base/Platform (Base/Off/Platform)
Switch
1. Ensure both "
buttons are pulled out.
2. Start engine.
3. On base control console, turn off/base/
platform (base/off/platform) key switch to
"
" off position.
Result: Engine should shut down and
aerial platform functions should not
operate.
4. On base control console, turn off/base/
platform (base/off/platform) key switch to
"
" platform position.
Ensure that you maintain three points
of contact to mount/dismount platform.
5. Enter platform and close gate.
6. On platform control console, select
"
" on position from engine start/on/off
switch.
SJ 46AJ
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
Off/Base/Platform
Key Switch
Emergency
Stop
Start/Function
Enable/
Emergency
Power Switch
" emergency stop
WARNING
December 2007
contained in this operating manual and on the aerial platform.
7. Select "
" start position from engine
start/on/off switch to start engine.
8. Dismount from platform.
9. On base control console, attempt to
activate each boom and platform switch
while holding function enable switch.
Result: All boom and platform functions
should not operate while holding function
enable switch.
10. Push in "
" emergency stop button to
turn engine off.
11. Pull out "
" emergency stop button.
Function Tests
Base/Off/Platform
Key Switch
Emergency
Stop