Base Control Console Test - Skyjack SJ46AJ Operating Manual

Articulating booms
Hide thumbs Also See for SJ46AJ:
Table of Contents

Advertisement

Section 2 - Familiarization
Base Control Console
2.4-2
Base Control Console
1.
On platform control console, pull out "
emergency stop button.
2.
For dual fuel engine, select fuel supply by moving
fuel switch to either "
propane gas position.
Ensure that you maintain three points
of contact to mount/dismount platform.
Test Base Emergency Stop Light
1. On base control console, pull out
"
" emergency stop button.
Result: Emergency stop light should
continuously illuminate.
2. Turn off/base/platform (base/off/platform)
key switch to "
3. Start engine by selecting "
position from start/function enable/
emergency power switch.
SJ 46AJ
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
Off/Base/Platform
Key Switch
Emergency
Stop
Start/Function
Enable/
Emergency
Power Switch
"
" gasoline or "
" liquid
WARNING
" base position.
" start
December 2007
contained in this operating manual and on the aerial platform.
Test Base Emergency Stop
1. Push in "
" emergency stop button.
Result: Engine should shut down and
aerial platform functions should not
operate.
2. Pull out "
" emergency stop button and
restart engine.
Test Function Enable Switch and All Boom
Functions
WARNING
Ensure that there are no personnel or
obstructions in test area and there is
sufficient room for boom to swing.
1. Do not hold "
" function enable switch.
Attempt to activate each boom and
platform switch.
Result: All boom and platform functions
should not operate.
2. Hold "
" function enable switch
and activate each boom and platform
function.
Result: All boom and platform functions
should operate as selected.
Function Tests
Base/Off/Platform
Key Switch
Emergency
Stop
Page 29