6.1.5

Minimum clearances

Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive
fields will be affected. In this case, the data transmission time can increase unpredictably or
a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
Table 6- 4
RF250R with ANT 1
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
RF250R with ANT 1
Operating distance (S
2...32
2...65
2...25
2...85
2...35
Minimum distances transponder edge to transponder edge
MDS D423 /
MDS D425
≥ 120 mm
)
a
MDS D126 / MDS D160 /
MDS D165 / MDS D200 /
MDS D339 / MDS D426 /
MDS D428 / MDS D460
≥ 150 mm
Antennas
6.1 ANT 1
RF250R with ANT 1
Limit distance (S
)
g
38
85
35
105
50
MDS D100 / MDS D124 /
MDS D139 / MDS D 261 /
MDS D400 / MDS D424
≥ 240 mm
163