Minimum Clearances; Rf300 - Siemens SIMATIC RF300 System Manual

Simatic sensors
Hide thumbs Also See for SIMATIC RF300:
Table of Contents

Advertisement

4.2.3

Minimum clearances

Minimum distance from transponder to transponder
The specified distances refer to a metal-free environment. For a metallic environment, the
specified minimum distances must be multiplied by a factor of 1.5.
Table 4- 20
RF300 tags
RF310R
RF320T
≥ 50
RF340T
≥ 60
RF350T
≥ 60
RF360T
≥ 60
RF370T
__
RF380T
__
The values are all in mm, relative to the operating distance (S
Table 4- 21
ISO tags
RF310R
MDS
≥ 120
D100
MDS
≥ 100
D124
MDS
≥ 120
D139
MDS
≥ 120
D160
MDS
≥ 120
D324
MDS
D421
MDS
D424
MDS
D428
MDS
D460
The values are all in mm, relative to the operating distance (S
SIMATIC RF300
System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04
RF340R
RF350R /
ANT 1
≥ 70
≥ 70
≥ 80
≥ 80
≥ 80
≥ 80
≥ 80
≥ 80
≥ 80
≥ 80
≥ 80
≥ 80
RF340R
RF350R /
ANT 1
4.2 Field data for transponders, readers and antennas
RF350R /
RF350R /
ANT 12
ANT 18
≥ 20
≥ 40
__
__
__
__
) between reader and tag
a
RF350R /
RF350R /
ANT 12
ANT 18
) between reader and tag
a
RF300 system planning
RF350R /
RF380R
ANT 30
≥ 40
≥ 120
≥ 40
≥ 140
≥ 50
≥ 150
__
≥ 120
__
≥ 130
__
≥ 150
RF350R /
RF380R
ANT 30
≥ 300
≥ 170
≥ 230
≥ 150
≥ 250
47