Siemens SIMATIC RF200 System Manual page 119

Hide thumbs Also See for SIMATIC RF200:
Table of Contents

Advertisement

5.3.6
Technical specifications of the RF220R reader
Table 5- 6
Product type designation
Radio frequencies
Operating frequency, rated value
Electrical data
Maximum range
Maximum data transmission speed
reader ↔ transponder
Typical transmission time for user data per byte
Transmission speed
Read/write distances of the reader
MTBF (Mean Time Between Failures)
Interfaces
Electrical connector design
Standard for interfaces for communication
Antenna
Mechanical specifications
Housing
Recommended distance to metal
Supply voltage, current consumption, power loss
Supply voltage
Typical current consumption
Permitted ambient conditions
Ambient temperature
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Technical specifications of the RF220R reader
Read
Write
for write access
for read access
Material
Color
During operation
SIMATIC RF220R
13.56 MHz
35 mm
ISO tags
approx. 1500 bytes/s
approx. 1500 bytes/s
0.6 ms
0.6 ms
19.2, 57.6, 115.2 kBd
see section "Field data (Page 39)"
501 years
M12, 8-pin
RS-422
integrated
Brass, nickel-plated
Silver
0 mm
24 VDC
50 mA
-20 ... +70 °C
Readers
5.3 SIMATIC RF220R
6GT2821-2AC10
119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf280r

Table of Contents