Readers
5.5 SIMATIC RF250R
5.5.5
Technical specifications of the RF250R reader
Table 5- 10
Product type designation
Radio frequencies
Operating frequency, rated value
Electrical data
Maximum range
Maximum data transmission speed
reader ↔ transponder
•
•
Typical transmission time for user data per byte
•
•
Transmission speed
Read/write distances of the reader
MTBF (Mean Time Between Failures)
Interfaces
Electrical connector design
Standard for interfaces for communication
•
•
130
LED
Meaning
Operating mode "with presence": Transponder present
•
Operating mode "without presence": Transponder present and command
•
currently being executed
There is an error. The number of flashes provides information about the cur-
rent error. You can find more information on error messages in the section
"Error codes of the RF200 readers (Page 329)". The optical error display is
only reset if the corresponding reset parameter ("option_1 = 2") is set (see
product information "SIMATIC RF200 Command Set
(https://support.industry.siemens.com/cs/ww/en/view/44864850)").
Technical specifications of the RF250R reader
Read
Write
for write access
for read access
RS-422
RS-232
SIMATIC RF250R
13.56 MHz
35 mm
ISO tags
approx. 1500 bytes/s
•
approx. 1500 bytes/s
•
0.6 or 1.2 ms
•
0.6 or 1.2 ms
•
19.2, 57.6, 115.2 kBd
see section "Field data (Page 39)"
430 years
M8, 4-pin
3964R protocol
•
ASCII protocol
•
System Manual, 07/2017, J31069-D0227-U001-A9-7619
6GT2821-5AC10
6GT2821-5AC40
SIMATIC RF200