Siemens SIMATIC RF200 System Manual page 52

Hide thumbs Also See for SIMATIC RF200:
Table of Contents

Advertisement

Planning the RF200 system
4.3 Installation guidelines
Table 4- 19
Flush-mounting of transponders and readers
Representation
52
Description
Problem:
Flush-mounting of transponders and
readers is possible in principle.
However, the size of the transmis-
sion window is significantly reduced.
The following measures can be
used to counteract the reduction of
the window:
Remedy:
Enlargement of the non-metallic
spacer below the transponder
and/or reader.
The transponder and/or reader are
10 to 20 mm higher than the metal
surround.
(The value x ≥ 100 mm is valid, for
example, for RF260R. It indicates
that, for a distance x ≥ 100 mm, the
reader can no longer be significantly
affected by metal.)
Remedy:
Increase the distances a, b to metal.
The following rule of thumb can be
used:
Increase a, b by a factor of 2 to 3
over the values specified for
metal-free areas
Increasing a, b has a greater
effect for readers or transpond-
ers with a large limit distance
than for readers or transponders
with a small limit distance.
System Manual, 07/2017, J31069-D0227-U001-A9-7619
SIMATIC RF200

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf280r

Table of Contents