Table 4- 26
Transponder
MDS D117
MDS D127
MDS D421
MDS D521
Table 4- 27
Transponder
MDS D117
MDS D127
MDS D160
MDS D421
MDS D422
MDS D425
MDS D428
MDS D460
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Reduction of field data due to metal, range as %: Transponder and RF250R with ANT 8
Without metal
Flush-mounted in metal;
distance all round 0 mm
Without metal
Flush-mounted in metal;
distance all round 0 mm
Without metal
Flush-mounted in metal;
distance all round 0 mm
Without metal
Flush-mounted in metal;
distance all round 0 mm
Reduction of field data due to metal, range as %: Transponder and RF250R with ANT 12
Without metal
Flush-mounted in metal;
distance all round 0 mm
Without metal
Flush-mounted in metal;
distance all round 0 mm
Without metal
1)
On metal, distance 10 mm
Without metal
Flush-mounted in metal;
distance all round 0 mm
Without metal
Flush-mounted in metal;
distance all round 0 mm
Without metal
On metal, distance 0 mm
Without metal
On metal, distance 0 mm
Without metal
1)
On metal, distance 10 mm
Flush-mounted in metal;
distance all round 0 mm
Planning the RF200 system
4.3 Installation guidelines
RF250R with ANT 8
Antenna without
Antenna flush-
metal
mounted in metal
100
65
100
70
100
75
100
75
RF250R with ANT 12
Antenna without
Antenna flush-
metal
mounted in metal
(all round 7 mm)
100
50
100
65
100
90
100
65
100
90
100
115
2)
100
110
2)
100
90
85
85
55
85
60
85
70
85
70
85
40
85
50
90
85
90
45
90
75
90
100
85
95
95
80
75
67