11 Ventilation, technical data, heat dissipation

11 Ventilation, technical data, heat dissipation
On-site ventilation:
Option
56
When installing an exhaust hood, observe the
following:
> VDI Directive 2052 and local construction
authority regulations on exhaust hoods.
The exhaust hood should protrude 300-500
mm over the front of the device.
> Install the device underneath an exhaust hood
if using a VarioSmoker.
> Install a grease filter into the protruding part
of the exhaust hood.
Exhaust hoods are available for most devices
(including for retrofitting). Consult the hood
installation guide for information on connecting
the hood.
Asphyxiation hazard!
Flue gases (CO and CO
Prevent unacceptable concentrations of harm-
ful flue gases within the installation room.
Set up the device under conditions of adequate
ventilation.
ATTENTION!
)
2