7 Water connection

7 Water connection
7.1

Prerequisites

Unit CMP XS
All other appliances
Appliance size
l/min
38
The device complies with all relevant regulations
(SVGW, KIWA, WRAS).
> The user must supply each device with its
own water tap.
> Rinse the water supply line before connecting
the device to water!
> Water pressure 1.5 - 6bar, 3bar recommend-
ed.
due to descaling of the steam generator:
> Drinking water protection for substance class
3 pursuant to EN 1717, such as a CA sys-
tem separator pursuant to EN 14367, must
be installed in the feed line on the tap at the
drinking water network connection point.
> The CA system separator is supplied for NL
and CH, and are available through RATIONAL
using part number 50.01.820 for other Euro-
pean countries.
meet the requirements for drinking water pro-
tection pursuant to EN1717 in as-delivered con-
dition.
> Flow rates required for each device (max.):
60
61
7
20
Connect the device to drinking water-quality
water.
Connect a flexible drinking-water connection
hose in accordance with EN 61770 or EN 13618
or of similar quality. Take any necessary safety
precautions with the water tap, such as backflow
preventers or CA system separators.
The water connection hose must comply with
country-specific hygiene standards for drinking
water hoses.
62
11
25
20
12
21
25
25
22
25