Rational SelfCookingCenter Original Installation Manual page 59

Hide thumbs Also See for SelfCookingCenter:
Table of Contents

Advertisement

12 Initial start-up
Self test
When first commissioning a new device, start a
one-time self-test. This test serves to adjust the
device to its specific ambient conditions.
It runs automatically, and takes between 45 and
65 minutes depending on the size of the unit; if
an UltraVent is in use, the test will take around
20 minutes longer.
> To perform the self-test, check the hook lad-
ders and the air baffle to ensure they are seat-
ed correctly.
>
The device must be connected to water,
wastewater, and electricity as per installation
instructions; gas devices must also be con-
nected to gas supply and exhaust lines.
>
The left side panel must be closed.
>
With tabletop units, insert a flat GN container
into the middle of the hook ladders, with the
opening facing the bottom.
> With floor units, insert two GN into the
mobile oven rack: one centered in front of
each fan, with the openings facing the bot-
tom.
> Do not open the cooking chamber door
during the self-test.
59