8 Gas connection

8 Gas connection
Australian Supplement to Gas Installation
Danger to life!
Connecting incorrectly may result in burns.
Observe local regulations.
Poisoning hazard!
Make sure that factory settings conform with
actual connection conditions:
> Perform exhaust gas analysis when first
commissioning steam- and convection burn-
ers (CO, CO
)
2
> record these values.
If undiluted CO levels are above 150ppm for
convection and 400ppm for steam, a compa-
ny-trained and certified technician must be
called in to check burner settings in accordance
with setting instructions, and adjust these set-
tings if needed.
Observe all local gas company regulations!
> To be installed only by authorised person in
accordance with AS 5601, local authority, gas,
electricity, any applicable statutory regulations
and manufacturer requirements.
> Particular attention should be given to rele-
vant requirements regarding ventilation.
> This appliance is not suitable for use in marine
environment.