9 Exhaust gas connection
9.2

Type B13

50
400 mm
Room air-dependent gas furnaces with fans in
front of burners and flow guards.
Type B13 installations may only be performed
with the original flow guards listed below.
With B13 installations, ensure that a vertical
updraft line is on hand.
The updraft line must end 400mm beneath the
grease filter. The device must be installed under-
neath an exhaust hood or a ventilation ceiling.
Monitor the exhaust vent to ensure that gas
is only fed to the burners when extraction is
ensured.
400 mm