8 Gas connection
Check the type of gas available and the dynamic
connection pressure against the values specified
on the device.
! mbar
Pipe diameter at least 3/4", in accordance with
local regulations.
Gas connection internal thread.
Gas shut-off valve on each device.
Gas connection with gas outlet possible.
All connection components installed on-site
must be checked in accordance with DIN-DVGW
(local gas supply company).
Secure the unit against slipping.
Use a suitable gas leak detector to check for
leaks in the gas supply and gas distribution with-
in the device.