[14]
Fuser station
[52]
Explosion
[53]
Risk of burning The components in the fuser station reach a sur-
[15]
Cleaning material
[55]
Caution
[56]
Eye contact;
allergic reac-
tions
[57]
Inhalation; al-
lergic reactions
[58]
Improper use
Cleaning the fuser station/soft fuser roller
There can be a high build-up of static charge
when vacuuming the toner spill. Always use an
industrial vacuum cleaner with a grounded suc-
tion tube, rubber nozzle and filter set for fine
dust. For larger toner quantities, the industrial
vacuum cleaner must be explosion proof.
face temperature of approximately 230
ing operation. Touching the components can
cause burns.
Do not touch any parts behind safety covers that
carry this icon:
[54]
Allow the printing system to cool down for at
least 30 minutes, with the fuser station open.
Wear the heat protection gloves.
The cleaning material is very flammable. Risk of
fire!
Do not allow the cleaning material to come into
contact with the eyes.
Rinse eyes with plenty of water and seek medi-
cal attention.
Do not inhale vapors from the cleaning material.
If, after inhalation, you experience symptoms
such as nausea, headaches or dizziness, go out
into the fresh air immediately and seek medical
attention if necessary.
Keep cleaning material out of the reach of chil-
dren and store it away from containers used for
food and drink.
o
C dur-
23