6. ASSEMBLY
6-13. Work clamp arm mechanism
1349B
After assembling, adjust the home position. (Refer to "7-20. Adjusting the home position".) After that, carry out a test
feed to check that the needle hole does not go outside the frames of the work clamp and feed plate. If the needle
hole goes outside the frames, adjust the position of the feed plate or readjust the home position.
81
BAS-342G
1. Feed plate
2. Bolts with washers [2 pcs]
3. Work clamp arm assembly
4. Bolts with washers [4 pcs]
5. Bolts [8 pcs]