Brother BAS-342G Service Manual page 20

Programmable electronic pattern sewer
Hide thumbs Also See for BAS-342G:
Table of Contents

Advertisement

2. FUNCTION SETTINGS
Data editing settings
Setting
No.
value
Sewing area limit in X direction
460
0
300
Sewing area limit in Y direction
461
0
200
Enlargement/reduction reference point
0
462
1
2
Enlargement/reduction for bar tacking
463
OFF
ON
Enlargement/reduction ratio in XY directions
OFF
464
ON
Storing parallel movement amount for sewing pattern
OFF
465
ON
Reading sewing data from external media into internal memory
0
1
466
2
Changing gear ratio correction method when reading from a 2DD floppy disk.
0
467
1
2
3
Retract point switching at parallel movement point
468
OFF
ON
Device settings
Setting
No.
value
Needle cooler device
550
OFF
ON
Tension release setting at the sewing start
551
0
3
Tension release timing during thread trimming [Units: 8-degree steps]
552
-10 - 1
11
[Units mm]
[Units mm]
Center of sewing frame
Sewing start position
Center of pattern
Bar tacking stitches (pitch approx. 1 mm or less) cannot be enlarged or reduced.
Bar tacking stitches (pitch approx. 1 mm or less) are also enlarged or reduced.
Disabled
Enlargement/reduction ratio settings are the same in X and Y directions (disabled
for user programs)
Initialized when program number or enlargement/reduction ratio is changed and
when power is turned off.
Initialized when program number or enlargement/reduction ratio is changed but
not when power is turned off.
[Normal mode] Programs are copied one by one into internal memory.
[Overwriting mode] Sewing data is overwritten into the temporary buffer area.
If sewing data with the same program number already exists in internal memory, it
is deleted.
[Interrupt mode] Sewing data is overwritten into the temporary buffer area.
If sewing data with the same program number already exists in internal memory, it
is not deleted, but only the data in the temporary buffer is used.
(If sewing data with the same program number already exists in internal memory
and the setting is changed to "0" or "1", the data in the temporary buffer will be
cleared.),
Automatic conversion based on model type (For the BAS-342G, data is read as
BAS-342A data and then converted.)
BAS-311A data is read.
BAS-326A data is read.
BAS-341A/BAS-342A data is read.
Disabled
The position moved to by parallel movement is recorded as the retract point.
Disabled
Needle cooler device is used (Option output No. 12)
[Units: No. of stitches]
-10: Early
0: Standard
Setting item
Setting item
1: Late
BAS-342G
Default
value
300
200
0
ON
OFF
OFF
0
0
OFF
Default
value
OFF
0
0