7-20-2. X-Y feed home position

1
Turn the pulley to set the needle to the needle up stop position.
2
TEST indicator and X-SCALE indicator illuminate.
3
4
Press the RESET key.
• Home position detection will be carried out, and the work clamp will stop at the
currently-registered home position.
* If you press the RESET key for 2 seconds or more at this time, the offset value will be reset
to "
0 ".
While pressing the
the power switch.
* Keep pressing the
displayed and the buzzer beeps once.
• "orG" will flash in the PROGRAM No. display and the
offset value (default: 0) will be displayed in the menu
display.
Press the SELECT key so that either the X-SCALE
indicator or the Y-SCALE indicator illuminates.
BAS-342G
7. ADJUSTMENT
keys simultaneously, turn on
keys until the model name is
5205Q 4443Q 4421Q
(Continued on the next page)
4570Q
104