4.2.1 Cursor Measurement Parameters

4
Other Functions
4.2 Cursor Measurement Function
○For horizontal cursor
With the cursor measurement valid, the measurement parameters and the
calculation result are automatically displayed at the upper left of waveform
display area. The type of measurement parameters in the horizontal
cursor is shown in Table 4-1.
Table 4-1: Measurement Parameters of Horizontal Cursors
Parameter
Description
Cursor1
Value of measurement target channel at the Cursor1
Cursor2
Value of measurement target channel at the Cursor2
MAX
Maximum value of measurement target channel between
Cursor1 and Cursor2
MIN
Minimum value of measurement target channel between
Cursor1 and Cursor2
P-P
(Peak to Peak: difference of MAX and MIN)
Absolute value of the result obtained by: MAX-MIN
○For vertical cursor
With the cursor measurement valid, the measurement parameters and the
calculation result are automatically displayed at the upper left of waveform
display area. The type of measurement parameters in the vertical cursor
is shown in Table 4-2.
Table 4-2: Measurement Parameters of Vertical Cursors
Parameter
Description
Time
Time width between Cursor1 and Cursor2
Cursor1
Value of measurement target channel at the Cursor1
Cursor2
Value of measurement target channel at the Cursor2
MAX
Maximum value of measurement target channel between
Cursor1 and Cursor2
MIN
Minimum value of measurement target channel between
Cursor1 and Cursor2
P-P
(Peak to Peak: difference of MAX and MIN)
Absolute value of the result obtained by: MAX-MIN
RMS
(RMS: Root Mean Square)
Data between Cursor1 and Cursor2; calculated actual value of
the measurement target channel
4-5