YASKAWA DX200 Instructions Manual page 21

Options instructions for pendant oscilloscope function
Hide thumbs Also See for DX200:
Table of Contents

Advertisement

165467-1CD
Pendant Oscilloscope
Function
2
Setting and Operation for Data Measurement
2.3 Setting Measurement Conditions
 Position
Sets the zero position of target channel. Specify the zero point within
the range of -5.0 to 5.0 [div] in the vertical axis of waveform display
area.
On the extreme left of waveform display area, a marker is provided
showing a zero point for each channel in which the current zero point
can be confirmed (see Fig. 2-6).
Fig. 2-6: Zero Point Marker
Zero point
maker
 Unit (rpm/div, %/div, U/div)
Selects the reference unit of target channel in the vertical axis scale.
(For description of the unit, refer to section 5.2 "Reference Unit" on
page 5-2.)
Displayed unit and its selection depend on the signal output by the
target channel.
Speed reference, Speed FB:
Unit [rpm/div]: selectable among 250, 500, 1000, and 2000
Torque reference:
Unit [%/div]: selectable among 33, 50, 66, and 100
Concurrent I/O signal:
Unit [U/div]: selectable among 0.2, 0.5, 1.0, 2.0, 5.0, and 10.0
Register:
Unit [-/div]: selectable among 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000,
2000, 3277, 5000, 6554, 10000, 13107, 20000, 32768, 50000 and
65535.
2-9
21 of 48
HW1481803