The tank should now be filled approximately 70-80%. US Water does not send extra media.
8. Be sure to remove the tape and wipe the top of the tank and distributor tube with a clean cloth.
9. Fill the tank with water until it is approx. 4" from the top. Be sure to let the carbon soak for a mini-
mum of 2 hrs.
10. Lubricate the o-rings on the head with food grade silicone lubricant*. (part #
Make sure that the upper basket (Figure B) is securely attached to the tank head. [* If food grade
ed)
silicone is not available, use corn or vegetable oil.]
11. Install the head back on the tank and tighten hand tight. Do not use tools to tighten the head or
damage may occur.
****NEVER USE A PETROLEUM BASED LUBRICANT OR VASOLINE****
12. Install the bypass on the tank head. Lubricate the O-rings on the bypass and hand tighten the nuts.