18
To connect the IntelliFloXF
communication cable to EasyTouch
Control System load center:
1. Switch the main power off to the load center.
2. Unlatch the two enclosure door spring latch, and
open the door.
3. Remove the two retaining screws securing the
high voltage cover panel, and remove it from the
enclosure.
4. Loosen the two access screws securing the control
panel.
5. Lower down the hinged control panel to access the
EasyTouch or IntelliTouch system circuit board.
6. Route the communication cable into the plastic
grommet (located on the lower left side of the load
center), up through the low voltage raceway to the
EasyTouch or IntelliTouch system circuit board.
7. Strip back the cable conductors 6 mm (1/4"). Insert
the two wires into the COM port screw terminals
on the EasyTouch and/or IntelliTouch system circuit
board. Secure the wires with the screws.
8. EasyTouch COM port (J20): Connect the GREEN
(#2) and YELLOW (#3) wires to the COM port screw
terminals (#2 and #3). Be sure to match the color
coding of the wires; YELLOW to YELLOW and
GREEN to GREEN. The Red wire is not connected.
Secure the wires with the screws.
Control Panel
Access Screw
Front Door
EasyTouch and/or IntelliTouch Control System
Load Center
XF
®
INTELLIFLO
and INTELLIPRO
Variable Speed Pump
®
or IntelliTouch
®
Control Panel
Access Screw
Retaining Screws
(for High Voltage
Cover Panel)
High Voltage
Cover Panel
Grommet (to Low
Voltage Raceway)
BLK
GRN
YEL
RED
XF
®
Variable Speed Pump Installation and User's Guide
®
IntelliTouch COM port (J7/8): Connect the GREEN
(#2) and YELLOW (#3) wires to the COM port (J20)
screw terminals (#2 and #3). Be sure to match the
color coding of the wires;YELLOW to YELLOW and
GREEN to GREEN. The Red wire is not connected.
Secure the wires with the screws.
Note: Multiple wires may be inserted into a single
screw terminal.
9. Close the control panel into its original position
and secure it with the two screws.
10. Install the high voltage cover panel and secure it
with the two retaining screws.
11. Close the load center front door. Fasten the spring
latch.
12. Switch the power on to the load center.
EasyTouch Control System Circuit Board
IntelliTouch Control System Circuit Board
EasyTouch
COMPORT
(J20)
Indoor Control Panel
IntelliChlor
IntelliFlo
RF Transceiver
IntelliTouch Personality
Board COM PORT
(J7/J8)

Advertisement