External Control with IntelliComm
Communication Center
Use the RS-485 communications cable to remotely
control the IntelliFloXF
Variable Speed Pump from an
®
IntelliComm communication center. The IntelliComm
communication center provides four (4) pairs of input
terminal connections. These inputs are actuated by
either 15 - 240 VAC or 15 - 100 VDC. Use the device
inputs, to control the programmed pump speeds.
Note: For the pump to accept commands from the
IntelliComm communication center, the pump must be
in the "Running Schedules" mode (LED above Start/
Stop button is on). If more than one input is active, the
highest number will be communicated to the pump.
The IntelliComm communication center will always
communicate to pump using ADDRESS #1.
Program Number Priority
If programs 1 and 2 are activated, program 2 will
run, regardless of the assigned speed (RPM). The
higher program number will always take priority.
Refer back to page 12 for instructions for setting up
Programs in the External Control menu.
External Control is for programming speeds that will
run when the IntelliComm communication center
controller sends it a command.
For example, Terminal 3 and 4 in IntelliComm system
will correspond to External Control Program #1. (5
and 6 to Ext Ctrl #2). Use the External Control feature
to program the IntelliComm communication center.
Connecting to EasyTouch
IntelliTouch
Control Systems
®
The pump can be controlled by an EasyTouch or
IntelliTouch control system via the RS-485 communication
cable. The EasyTouch and/or IntelliTouch control
system starts, stops and controls the speed of the pump.
EasyTouch and/or IntelliTouch systems rewrite the pump
memory when a command is given. This can take several
seconds and can cause a delay until the pump physically
responds.
The pump control panel is disabled when communicating
with an EasyTouch and/or IntelliTouch system. The
EasyTouch and/or IntelliTouch system will not start
communicating with the pump until the pump is
assigned to a circuit. The default pump address is "1"
(only address for EasyTouch system).
CONNECTING TO AN AUTOMATION SYSTEM
®
and
®
XF
®
INTELLIFLO
and INTELLIPRO
Wiring Terminal Descriptions for IntelliComm
Communication Center
Terminal
Terminal
Voltage
Number
Name
Power
100 - 240
1-2
Supply
VAC
15 -240
VAC
Program
3-4
or
1
15 - 100
VDC
15 -240
VAC
Program
5-6
or
2
15 - 100
VDC
15 -240
VAC
7-8
Program
or
3
15 - 100
VDC
15 -240
VAC
Program
9-10
or
4
15 - 100
VDC
RS-485
11
+ Data:
-5 to +5
12
Yellow
VDC
- Data:
Green
Ground
IntelliComm Communication Center
See page 8 for details about how to check and or set
the pump address. For more information, refer to the
IntelliTouch (P/N 520100) or EasyTouch automation
system User's Guide (P/N 520584).
Installation and User's Guides are available at:
www.pentairpool.com/pool-owner/manuals.
XF
®
Variable Speed Pump Installation and User's Guide