MENU
Pump Menu: Priming
PRIMING
Disabling Priming with an Automation System
When
the
IntelliFloXF
is connected to an automation control system,
(IntelliTouch
,
EasyTouch
®
Systems), the priming feature on the pump cannot
be disabled by the external automation control
system only. It must also be disabled on the pump
itself.
If priming is enabled on start up, the pump responds
to its internal settings before responding to commands
from an automation control system.
If the pump is connected to an automation control
system and priming is not desired, disable the
priming feature on both the pump and the
automation control system.
Refer back to page 14 for instructions on accessing
the priming menu and features.
1. Disable priming on automation control system.
3. Disable priming on pump.
Variable
Speed
Pump
®
or
SunTouch
Control
®
®
XF
®
INTELLIFLO
and INTELLIPRO
To disable priming with an automation system:
1. Disable the priming feature on the automation control
system at the load center or using an IntelliTouch or
EasyTouch system remote. (Refer to the automation
control system user's guide for additional information).
2. Temporarily disconnect the RS-485 communication
cable.
3. Open the lid to the control panel to disable priming
on the pump. Press Menu, use the arrow buttons to
scroll and select "Priming", then select "Disabled" (the
factory default is set to "Enabled"). Press Escape to
exit the menu.
4. Once priming is disabled, reinstall the RS-485
communication cable.
2. Disconnect the RS-485 communication cable.
4. Reinstall the RS-485 communication cable.
XF
®