16
MENU
Pump Menu: Anti Freeze
ANTIFREEZE
The sensor for Anti Freeze is in the drive, on top of the
motor. This feature allows you to set a speed (450 RPM
- 3450 RPM) that runs when the IntelliFloXF
Speed Pump goes into anti freeze mode. The tempera-
ture level that you wish anti freeze mode to start can
also be set.
IMPORTANT NOTE: This feature is for protection of
the pump. Do not depend on the anti freeze feature for
freeze protection of the pool. Certain situations could
cause the pump to sense a different temperature than
actual air temperature.
Your automation systems air temperature sensor should
be used to sense actual temperature. For example, if
the pump is located indoors, the temperature of the
room does not indicate the outdoor temperature. The
pump does not sense the water temperature.
To access the Anti Freeze menu:
1. Check that the green power LED is on.
2. Press Menu.
3. Use the Down arrow to scroll to "Anti Freeze"
and press Select.
4. The factory default for Anti Freeze is "Enabled".
To disable Anti Freeze, press Select to highlight
"Enabled".
5. Press the Up arrow - "Disabled" is displayed.
6. Press Enter to save.
1000
Set Speed
Setting the Anti Freeze Pump Speed
ANTI FREEZE
XF
®
INTELLIFLO
and INTELLIPRO
Variable
®
12:15p
RPM
DISABLED/ENABLED
SET SPEED
PUMP TEMPERATURE
Anti Freeze Menu Options
XF
®
Variable Speed Pump Installation and User's Guide
To Set Anti Freeze Speed and Pump Temperature:
1. With Anti Freeze displayed on the screen, press
the Down arrow -
factory default is 1000 RPM.
2. Press Select to change the speed. The cursor
will highlight the first column (ones).
3. Use the Up or Down arrows to set speed (450 -
3450 RPM).
4. Press Enter to save the speed.
5. Press the Down arrow to Pump Temperature
(the temperature the pump will activate
AntiFreeze, default is 40° F/4.4° C).
6. Press Select to change the setting. The cursor
will highlight the first column. Can be set
to 50° F (4.4° C - 10° C).
7. Press Enter to save the temperature setting.
Note: To cancel any changes, press Escape to
exit without saving.
8. Press Escape to exit.
40
Pump Temperature
Setting the Anti Freeze Pump Temperature
Disabled / Enabled - Default: Enabled
Set Speed (750 RPM - 3450 RPM) Default 1000 RPM
40° F - 50° F (4.4° C - 10° C) Default: 40° F (4.4° C)
"Set Speed" is displayed. The
40° F
12:15p
F
°

Advertisement

loading

This manual is also suitable for:

Intelliproxf