K5 Drinking Water Station
7. Non-Air Gap Faucet Installation
9. Faucet Connection to Unit
to white
collet on faucet
11. Air Charge Tank Installation
⅜" plug –
part #10641
to air tank
Note: RO air charge valve assembly must be changed out for correct function with air charge tank.
Section 7
8. Non-Air Gap Faucet Connections
faucet
rubber gasket
mounting washer
washer
lock washer
nut
10. Water On Water (WOW) Tank Installation
For Air charge tank installation, skip to Step 11.
to green
collet on tank
to yellow
collet on tank
plug
(yellow collet)
green
Drinking Water Systems
Page 12
green collet
use air charge kit - part #12797C
(kit includes ⅜" plug - #10641,
air charge valve assembly - #13886)
hand tighten
Do not over torque.
Torque to 20 -25 inch
lbs. turn clockwise
until stops
Revised: 09/2016
⅜" quick connect
from white collet