Sanitization Procedure For K5 Air Charge Install – Household Bleach - Kinetico K5 Manual

Drinking water station
Hide thumbs Also See for K5:
Table of Contents

Advertisement

Section 5: Sanitization Procedure for K5 Air Charge Install – Household
Bleach (unscented) – uses Sanitization Kit Part No. 9392A
Note: The following steps should be taken immediately after installation; no water should be in the unit.
Safety glasses
1. Attach anti-spray line
The faucet should be closed.
anti-spray line
4. Install cartridge plugs in
all locations, except
prefilter
Install 4 plugs in these locations.
(RO, Auxiliary 1, Auxiliary 2, Post)
8. Close feed / close tank
Revised: 09/2016
and rubber/latex gloves must be worn during sanitization.
2. Close feed / open tank
The feed valve
should be closed.
5. Add 5 mL unscented
bleach to a sanitization
cartridge that is half full
of clean water.
9. Slowly crack open faucet
to depressurize the system
WARNING: Do not
open faucet all the
way. Air, water and
chemical solution will
spray out forcefully.
Be prepared to
control the
anti-spray line.
Drinking Water Systems
Page 21
K5 Drinking Water Station
3. Confirm jack screw is
closed and the standard
tank spacer (gray) is
installed in the RO shutoff
position.
The tank valve
should be open.
6. Slowly open feed valve
7. Wait 4 minutes
prefilter position
Note: You may hear
a buzzing sound
from the unit. This is
normal for start-up.
Check for leaks.
10. Allow system to depressurize
– leave faucet open
Note: Do not over tighten.
kit part #12797C
(see page 5 of installation instructions)
Section 7

Hide quick links:

Advertisement

Table of Contents
loading