Conversion Instructions For 1522 Valve #1 From Carb To Non/Carb - Cornelius CB1522 Installation Manual

Intellicarb ice cooled dispenser
Hide thumbs Also See for CB1522:
Table of Contents

Advertisement

Conversion Instructions for 1522 Valve #1 from Carb to Non/Carb

!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
!
WARNING:
Water and CO
to the system must be turned off and the system depressurized prior to performing this service.
2
Failure to comply could result in serious injury, death or damage to the equipment.
1. Remove the cup rest, front panel, and drip tray.
2. Remove insulation pad, 2 screws, and bracket (as shown above on page 12).
3. Pull out a plug fitting from the rear connection of the manifold.
4. Disconnect soda line from valve #1.
5. Assemble straight fitting and oetiker clamp to soda line from valve #1 (as shown on page 12).
6. Assemble soda line from valve #1 to manifold.
7. Assemble hose plug and clamp oetiker to soda line valve #1 (as shown on page 12).
8. Reassemble bracket, 2 screws, and insulation pad.
9. Reassemble drip tray, front panel, and cup rest.
Drop-In Installation
1. Install dispenser in counter following standard procedures.
2. Use the Template supplied to mark the location of the hole to be cut into the counter top. Cut the hole as
marked and remove the material.
3. Apply the double stick tape (if supplied with the loose shipped parts).
NOTE: To comply with the National Sanitation Foundation (NSF) requirements, the unit must be
sealed to the counter top.
4. Liberally apply a sealant, such as Dow Corning RTV 731 or equivalent, to the unit flange bottom surface.
5. Lower the unit into position to complete the seal of the rim to the counter top. Apply additional sealant
around the rim to ensure a complete seal.
NOTE: Do not move the unit after positioning or the seal will be broken.
6. Remove any excess sealant.
NOTE: For non-electrical valves, skip the next step.
7. Mount the Transformer power supply under the counter, in a position to allow access to the electrical outlet
and to allow the 24V power cord to reach the dispenser.
8. Install the drain hose to the ice bin drain fitting and route the drain hose to a permanent drain.
9. Mount secondary CO
tion, no more than 7 feet from the unit.
© 2003-2017, Cornelius Inc.
regulator, carbonator pump with motor, and valve transformer in a convenient loca-
2
- 13 -
IntelliCarb Drop-In Ice Cooled Installation Guide