IntelliCarb Drop-In Ice Cooled Installation Guide
Trouble
Drink has off-taste or odor
(water contamination)
Publication Number: 630460204INS
TROUBLESHOOTING
Probable Cause
A. Leaking check valves.
B. Too much plumbers pipe com-
pound on pipe joints.
C. Soda water and beverage lines
made of brass or copper.
D. High chlorine level.
E. Tank corrosion.
F. Contaminated CO
2
- 38 -
Remedy
A. Replace O-Rings in double check
valve or replace double check
valve. See check valve installation
instruction section.
B. Remove pipe compound and
clean joints. Use PTFE pipe
thread tape.
C. Carbonated water reacts with
brass or copper and should not be
dispensed through lines of this
material. Replace lines with stain-
less steel or beverage grade plas-
tic.
D. Install water filter to eliminate
chlorine in excess of 1.5 ppm.
Use type that do not remove all
chlorine.
E. Replace tank.
F. Check that CO
is beverage
2
grade.
© 2003-2017, Cornelius Inc.