Cornelius Liquid Base Beverage Dispenser Installation & Operation Manuals
Cornelius Liquid Base Beverage Dispenser Installation & Operation Manuals

Cornelius Liquid Base Beverage Dispenser Installation & Operation Manuals

Cornelius liquid base beverage dispenser installation & operators manual
Hide thumbs Also See for Liquid Base Beverage Dispenser:

Advertisement

Liquid Base Beverage Dispenser
INSTALLATION & OPERATORS MANUAL
Part No. 630460001
June 4 1996
Control Code A
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This Installation Manual must be read and understood before starting to install or operate this equipment.
IMI CORNELIUS INC; 1996
IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone (800) 238–3600
Facsimile (612) 422–3232
Printed in U.S.A.

Advertisement

Table of Contents
loading

Summary of Contents for Cornelius Liquid Base Beverage Dispenser

  • Page 1 Liquid Base Beverage Dispenser INSTALLATION & OPERATORS MANUAL Part No. 630460001 June 4 1996 Control Code A THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Installation Manual must be read and understood before starting to install or operate this equipment. IMI CORNELIUS INC; 1996 IMI CORNELIUS INC.
  • Page 2: Table Of Contents

    TABLE 2. LOOSE-SHIPPED PARTS FIGURE 1. CONNECTION TO EXISTING SODA SYSTEM COOLANT IMI CORNELIUS INC. 1996 TABLE OF CONTENTS ............. . .
  • Page 3: General Description

    (not later than 15 days from date of delivery) and immediately reported to the delivering carrier. Request a written inspection from the carrier’s claims inspector to substantiate claim. File claim with the delivering carrier not with IMI Cornelius Inc. Table 1. Design Data 40 degrees F (4.4 degrees C) to...
  • Page 4: Unpacking And Inspection

    UNPACKING AND INSPECTION CAUTION: Unit must be lifted by the S/S tower to avoid damage. Do Not lift using valve housings. Unpack a Unit as follows: 1. Open carton. 2. Lift Unit from carton. 3. Retain installation manual, and loose shipped parts. 4.
  • Page 5: Countertop Hole Location (Tubing Access)

    COUNTERTOP HOLE LOCATION (TUBING ACCESS) 1. Using the template provided, layout the location of the access hole. 2. Cut the access hole in the counter. Be sure there are no sharp edges to damage the tubing. 3. Move the Unit into position over the hole and attach the tower to the counter. 4.
  • Page 6: Connect Concentrate Tubing

    7. Check all connections for leaks before insulating the tubing. To Heat Exchanger Inlet Tubing must be insulated to prevent condensation Cold Carbonated Water From Cooling Unit Syrup Tubing Cold Carbonated Water Return to Cooling Unit FIGURE 1. CONNECTION TO EXISTING SODA SYSTEM COOLANT CONNECT CONCENTRATE TUBING Connect concentrate tubing to the Unit as follows: 1.
  • Page 7 2. Carefully tilt the connected Unit up to expose the base. 3. Apply a silastic sealant e.g. Dow Corning RTV 731 or equivalent on all base edges. 4. Lower Unit into exact operating position on the countertop. 5. Fasten the tower to the countertop. 6.
  • Page 8 STRAINER POTABLE WATER SOURCE WATER PRESSURE REGULATOR COOLANT FROM EXISTING SOFT DRINK SYSTEM PRIMARY REGULATOR 70-80 PSI CHECK VALVE CYLINDER MULTI-FLAVOR TOWER B-I-B INSTALLATION BAG-IN-BOX (3) LINE LEGEND PLAIN WATER CONCENTRATE CONCENTRATE PUMP (3) MANIFOLD 630460001...
  • Page 9: Preparation For Operation

    Connect concentrate tubing to concentrate Sources Connect concentrate tubing to concentrate sources for bag-in-box (or tank). Make Electrical Connections Mount the transformer beneath the tower and route the 24V lead up into the tower and connect to the plugs in the tower for the valves and merchandiser.
  • Page 10: Setting The Portion Control

    LED Indicator Light Note: Check local specifications for dispensed product water to syrup ratio specifications. If the ratios are correct, proceed to Step I. If the ratios are not correct, proceed to step H. Turn valve syrup flow control labeled “S4” (right-side control) adjusting screw to the left (COUNTER- CLOCKWISE) for less syrup or to the right (CLOCKWISE) for more syrup.
  • Page 11: Sanitizing The System (Usa)

    SANITIZING THE BAG-IN-BOX CONCENTRATE SYSTEMS This is a procedure for sanitizing concentrate systems of the Liquid Base Beverage Dispenser. SANITIZE THE BAG-IN-BOX SYSTEM AS FOLLOWS: 1. Disconnect the concentrate tube-end connectors from the bag-in-box containers.
  • Page 12 15. Remove the tube-end connectors from the detergent. 16. Dispose of unused detergent in a sanitary sewer, not in a storm drain. Wash the container thoroughly. 17. Fill the 5-gallon container with potable (drinking) water. Place the tube-end connectors in the water. 18.
  • Page 13: Warranty

    IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un- der normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or Wilshire prod- uct, in your country, please write, fax or telephone the IMI Cornelius office nearest you. Please provide the equipment model number, serial number and the date of purchase.

Table of Contents