IntelliCarb Drop-In Ice Cooled Installation Guide
A
W
-T
DJUST
ATER
1. Remove valve cover and install syrup separator over the diffuser and through the nozzle.
2. Hold cup under valve and dispense beverage for a specific time (i.e. 2 seconds).
NOTE: Water and syrup must be cold before checking ratios.
3. Adjust carbonated water flow to the desired rate (such as 90 to 110 ml (3 to 3.75 oz.) per second).
4. Turn the flow adjuster 1/4 of a turn at a time and recheck the flow. To increase reading turn clockwise.
5. Set syrup flow adjuster to get the desired ratio.
6. Test the valve and adjust until a consistent ratio is delivered three consecutive times.
7. Repeat procedure for other valves.
Cornelius
Flowmatic
Cornelius
Flowmatic
Cornelius
Flowmatic
Cornelius
Flowmatic
Cornelius
Publication Number: 630460204INS
-S
R
O
YRUP
ATIO
Water-To-Syrup
ratio cup
Manufacturer
Portion Control
Pushbutton
Autofill Lever
Non-Electric
Figure 15.
Valve Type
Maximum Operating
130 psi
100 psi
130 psi
100 psi
Lever Type
130 psi
100 psi
130 psi
100 psi
130 psi
- 20 -
Separator
Pressure
© 2003-2017, Cornelius Inc.